Pepperl+Fuchs KCD2-SON-Ex1.R1 Switch Amplifier.
Technical specifications
- Signal type: Digital Input
- Safety Integrity Level (SIL): SIL 2
- Rated voltage: 19 ... 30 V DC
- Rated current: 18 ... 14 mA
- Rated voltage: 19 ... 30 V DC with external resistance > 2 kΩ, e. g. 16-channel ProSafe DI card SDV144 from Yokogawa
- Output I, II: signal or fault message, passive transistor output (resistive); 0-signal: 33 kΩ ± 5 % + voltage drop 6.5 V ± 0.5 V; 1-signal: voltage drop 6.5 V ± 0.5 V; fault: > 100 kΩ
- Ambient temperature: -20 ... 60 °C (-4 ... 140 °F); extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions
- Degree of protection: IP20
- Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001