Pepperl+Fuchs LMC-Ex Magnetic Immersion Probe for Continuous Measurement.
Technical specifications
- Connection: version I: 2-wire, 4 ... 20 mA; version O4: 3-wire, potentiometer connection approx. 40 kΩ
- Accuracy: resolution:; - version LMC5: 5 mm; - version LMC15: 15 mm
- Process temperature: -20 ... 100 °C (-4 ... 212 °F)
- Process pressure (static pressure): ≤ 16 bar (232.1 psi)
- Density: version S1: ≥ 0.6 g/cm3; version S2: ≥ 0.8 g/cm3; version S3: ≥ 0.7 g/cm3
- Ambient temperature: terminal box: -50 ... 60 °C (-58 ... 140 °F)
- Degree of protection: IP66 / IP68
- Connection: Version I: 2 terminals, max. 2.5 mm2; Version O4: 3 terminals, max. 2.5 mm2
- Material: float, guide tube, process connection: stainless steel 1.4571/316Ti; terminal box: aluminum die-casting
- Process connection: thread G1-1/2A, G2A to DIN/ISO 228/1